• Descargas
  • Últimas noticias
  • Eventos
  • ESPAñOL
    AUSTRIANDEUTSCHENGLISHFRANçAISITALIANONEDERLANDSSUOMISVENSKAVLAAMS
Eltako
  • Página web
  • Aplicaciones
    • Seguridad
    • Clima interior
    • Iluminación
    • Sombreado
    • Referencias
  • Productos
    • Professional Smart Home
    • Professional Standard
    • Accesorios
  • Servicio
    • Descargas
    • Eventos
    • Preguntas y respuestas
    • Professional Smart Home-Blog
  • Empresa
    • Socios y alianzas
    • Sostenibilidad
    • Social Media
    • Contacte con
    • Historia
    • Carrera

More results...

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
page
post
blog

TODOS LOS CONTACTOS

Oficina Central Alemania (Michael Länge, Head of Export) +49 (0)711 94350000 export@eltako.de


Thomas Klassmann (Gerente de ventas para España) +34 650 959702 klassmann@eltako.com


Oriol Montsec Fuego (Representante de ventas / soporte técnico Zona Catalunya) +34 692 835972 oriol@eltako.com


Ruben Prieto Serrano (Tecnico comercial Zona Levante, Murcia, Albacete) +34 672 395274 ruben@eltako.com


TODOS LOS CONTACTOS
Inicio / Professional Standard / Temporizadores, temporizadores multifuncionales y el interruptor horario / MFZ12DDX-UC
MFZ12DDX-UC

MFZ12DDX-UC

Digital settable multifunction time relay, 1 CO contact 10A

1 CO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 2000W*. Standby loss 0.05–0.5 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 15(L) for this. This gives an additional standby consumption of only 0.1 Watt. Universal control voltage 8 to 230V UC. Supply voltage same as the control voltage. Both functions and times are entered at the touch of a key and indicated digitally on an LC display. Only two keys are required for this purpose. When setting the time all values can be entered within preset time ranges (0.1 to 9.9 or 1 to 99 seconds, minutes or hours). The longest possible setting is 99 hours. 600 settings are possible. The time setting is continuously displayed digitally. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. Functions: RV = off delay. AV = operate delay. AV+ = operate delay additive. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse controlled pickup delay (e.g. automatic door opener). IF = pulse shaper. EW = fleeting NO contact. AW = fleeting NC contact. With TI, TP, IA, EAW, ARV and ARV+ functions, a different second time can be entered also with different time ranges. Setting the times and functions: The LCD component to be changed is selected by pressing the MODE key. The component accessed flashes. Press the SET key to change the component accessed. This may be the function, the time ranges, time T1 or time T2 (on TI, TP, IA, EAW, ARV and ARV+ only). Pressing the MODE key terminates each input. Once the time has been set with MODE, no more components are flashing. The timing relay is now ready to operate. Press the MODE key again to restart the input cycle. All the entered parameters are retained if they are not changed using SET. 25 sec. after the last operation and if the component still flashes the input cycle is automatically terminated and the previously made changes lapse. Functions of the LC display: If the ON or OFF function was selected, no time is displayed, only ON and OFF and a contact symbol in the correct position. On all other functions, the set time, the function code and the contact symbol are shown in the correct position (open or closed).The clock symbol flashes while the set time is elapsing and the remaining time is shown. Safety in the event of a power failure: The set parameters are stored in an EEPROM and are therefore immediately available again when the power supply is restored after a power failure. * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.

Art.-Nr.: 23001004 68.10€/St. *

* Recommended retail price plus VAT.

Data sheet
MFZ12DDX-UC
Flow chart
MFZ12DDX-UC

Otros también vieron:

WSZ110CEE-16A+PRCD MID

Mobile single-phase energy meter personal protection intermediate switch PRCD, with MID

WSZ110CEE-16A+PRCD MID

Data sheet Operación manual WSZ110CEE-16A+PRCD_28016113-1_gb.pdf
BPD55-FT55

Blisterpack dimming

BPD55-FT55

Data sheet
IFE12-10TS

Impulse switch with monostable relay 10A/250V AC

IFE12-10TS

Data sheet
HP1

Mounting plate

HP1

Data sheet
Descarga o en línea

Pida ahora el catálogo actual de productos 2023!

High resolution 27.8MB Low resolution 13.2MB
Servicio de contacto
  • Empresa
    • Socios y alianzas
    • Sostenibilidad
    • Social Media
    • Contacte con
    • Historia
    • Carrera
  • Aplicaciones
    • Seguridad
    • Clima interior
    • Iluminación
    • Sombreado
    • Referencias
  • Productos
    • Professional Smart Home
    • Professional Standard
    • Accesorios
  • Servicio
    • Descargas
    • Eventos
    • Preguntas y respuestas
    • Professional Smart Home-Blog
© Copyright 2023 Eltako GmbH
  • FAQ
  • CoC
  • Pie de imprenta
  • INFORMACIÓN SOBRE PROTECCIÓN DE DATOS PARA CLIENTES E INTERESADOS

Newsletter abonnieren