• Downloads
  • Ultime notizie
  • Eventi
  • ITALIANO
    AUSTRIANDEUTSCHENGLISHESPAñOLFRANçAISNEDERLANDSSUOMISVENSKAVLAAMS
Eltako
  • Home
  • Panoramica delle applicazioni
    • Sicurezza
    • Temperatura interna
    • Illuminazione
    • Ombreggiatura
    • Riferimenti
  • Prodotti
    • Professional Smart Home
    • Professional Standard
    • Accessori
  • Servizio
    • Downloads
    • Eventi
    • Domande e risposte
    • Professional Smart Home-Blog
  • Azienda
    • Partner e alleanze
    • Social Media
    • Contatti
    • La storia
    • Carriera

More results...

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
page
post
blog

AIUTO RAPIDO - I NOSTRI NUMERI DI SERVIZIO

Persona di contatto Germania (Michael Länge, Head of export) +49 (0)711 94350000 export@eltako.de


Carlo Palmieri (Direzione vendite) +39 329 6897235 carlo.palmieri@eltako.com


Luca Ziosi (Assistenza tecnica e commerciale) +39 320 3660345 luca.ziosi@eltako.com


Nicola Carli (Assistenza tecnica e commerciale) +39 320 6350851 nicola.carli@eltako.com


Tutti i contatti
Home / Professional Standard / Luci scale e timer di ritardo alla diseccitazione / TLZ12-8plus
TLZ12-8plus

TLZ12-8plus

Staircase time switch, 1 NO contact 16A

1 NO contact not potential free 16A/250V AC. 230V LED lamps up to 600W, energy saving lamps ESL up to 200W, incandescent lamps up to 2300W. Control voltage 230V and/or 8..230V UC. Switch-off early warning and permanent light by pushbutton switchable. Standby loss 0.7 watt only. With ESL optimisation and multifunction. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Zero passage switching to protect contacts and lamps. The noiseless electronics do not even bother the sensitive ear – unlike many synchronous motors with mechanical gears. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic ­synchronisation after installation has terminated. Control voltage, supply voltage and switching voltage 230V. In addition electrically isolated universal voltage from 8 to 230V UC. 3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection. Glow lamp current up to 50mA, dependent on the ignition voltage of the glow lamps. Precise variable time range from 1 to 30 minutes, settable by minute scale. Permanent light switch with the big rotary switch. If the function TLZ is set, the lighting is switched on again after a power failure provided the set time has not yet elapsed. With double connections for pushbutton and lamp in order to connect either above or below or only below. If switch-off early warning function is switched on, the light starts flickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals. If permanent light by pushbutton is switched on, permanent light can be switched on by pressing the pushbutton longer than 1 second. This is switched off automatically after 60 minutes or by pressing the pushbutton longer than 2 seconds. If both switch-off early warning function and permanent light by pushbutton are switched on, the switch-off early warning function is activated before the permanent light switches off. When energy saving lamps ESL are completely or partially switched, then set the switch-off early warning and the permanent light by pushbutton on the right hand side of the rotary switch. If the function TLZ is selected the time can be extended within the first second after switching on or resetting by pressing the pushbutton repeatedly up to three times (incrementing). Each momentary-contact ­control increments the set time once. With multifunction: The following functions can be selected optionally: ES (impulse switch), ER (relay), ESV (impulse switch with release delay). If the function ESV is set the time ranges (t), which can be set with the middle rotary switch are as follows: 1 = 2min, 2 = 5min, 3 = 10min, 4 = 15min, 6 = 25min, 8 = 35min, 10 = 45min, 12 = 60min, 20 = 90min, 30 = 120min. In this function the impulse switch automatically disconnects after the set delay is timed out, if a manual OFF command has not been given. Switch-off early warning and permanent light by pushbutton can also be switched on in this position. Forgotten permanent light is switched off after 2 hours.

Art.-Nr.: 23100832 55.90€/St. *

* Prezzo al pubblico suggerito IVA esclusa

Data sheet
TLZ12-8plus
TLZ12-8plus

ALTRI HANNO VISTO ANCHE:

DSZ14DRSZ-3x80A MID

RS485 bus two-way three-phase meter with display, MID approval

DSZ14DRSZ-3x80A MID

Datasheet Manuale operativo DSZ14DRSZ-3x80A_28465715-1_gb.pdf
WSZ110CEE-16A+PRCD MID

Mobile single-phase energy meter personal protection intermediate switch PRCD, with MID

WSZ110CEE-16A+PRCD MID

Data sheet Manuale operativo WSZ110CEE-16A+PRCD_28016113-1_gb.pdf
IFE12-20.13

Impulse switch with bistable relay 10A/250V AC

IFE12-20.13

Data sheet
SU12DBT/1+1-UC

2-channel timer with display and Bluetooth

SU12DBT/1+1-UC

Datasheet_S2U12DBT_1+1-UC.pdf Declaration of conformity Manuale operativo SU12DBT_1+1-UC_23200902-1_gb.pdf
 PER POSTA, DOWNLOAD O ONLINE

SCARICA O ORDINA ON-LINE IL CATALOGO PRODOTTI 2023

Alta definizione 25.7MB Bassa definizione 13.5MB
Contattare il Servizio
  • Azienda
    • Partner e alleanze
    • Social Media
    • Contatti
    • La storia
    • Carriera
  • Panoramica delle applicazioni
    • Sicurezza
    • Temperatura interna
    • Illuminazione
    • Ombreggiatura
    • Riferimenti
  • Prodotti
    • Professional Smart Home
    • Professional Standard
    • Accessori
  • Servizio
    • Downloads
    • Eventi
    • Domande e risposte
    • Professional Smart Home-Blog
© Copyright 2023 Eltako GmbH
  • Domande e risposte
  • CoC
  • Termini di consegna
  • Impronta
  • Informativa sulla privacy

Newsletter abonnieren