Configuration page

 

The Configuration page is split into six subsections :

 

Network Settings

Proxy

Access Control

Certified Time

WebAdmin

Backup

Borrowing

 


 

Network Settings:

 

 

 

Bind Address

Here you may edit which network adapter (virtual adapter) the CodeMeter Runtime Server will be bound to. This is very useful if your PC has several network adapters and should run as a network license server.

By default the CodeMeter Runtime Server uses the first detected network adapter (NIC).

Network Port

Port 22350 is the standard setting for CodeMeter communication. You may edit this value to your needs. In this case make sure that all CodeMeter Runtime Servers use the same port, if you want to use an application via the network.

UDP Waiting Time

Specifies the maximum UDP wait time.
This time specifies the maximum time interval in which UDP requests (requests via the UDP protocol) must be answered.

Run Network Server

If this option is enabled, the specified PC may be used as a CodeMeter Network Server.

Server Search List

 

On the Server Search List you can define the access to specific CodeMeter Servers. In this case the client only searches for these servers. To do so, just set the DNS name or the IP address of the CodeMeter Server in the Server Search List.

If the CodeMeter Server is located in a different subnet, it is strongly recommended that you use the IP address of the CodeMeter Server in the Server Search List!

 


 

Proxy:

 

 

Proxy support

Enable or disable the Proxy Server support; this option has to be enabled if you are using a proxy server!

Proxy Server

Set the IP address of your proxy server.

Proxy Port

Set the port number of your proxy server.

Authentication

Enable or disable the proxy server authentication.

Proxy User

User ID for the proxy server.

Proxy Password

User password for the proxy server.


 

Access Control:

 

 

Clients:

Shows a list of all CodeMeter client computers which have permission to use the CodeMeter Server (check out a license).

If this list is empty (default settings) all CodeMeter Clients are allowed to use the CodeMeter Server.

Add:

To allow a special CodeMeter Client to use the CodeMeter Server, just click on the "Add Button" and enter the IP address or the DNS name of the client into the input box. (To REMOVE a Client, highlight it and click “remove”.)

Access FSB

If this feature is enabled (box is checked), CodeMeter Clients or developer PCs can access the CodeMeter Firm Security Box (FSB). To disable this feature, disable the check-box.

This Feature is only useful for CodeMeter Licensors!


 

Certified Time:

 

 

Time Server

Specify the access order or add/remove the IP address or the URL of a CodeMeter Time Server.

The default values shown above are URL addresses of WIBU-SYSTEMS CodeMeter Time Servers.

Time Out

Set the Time out value of the CodeMeter Time Servers.


 

WebAdmin:

 

 

 

Remote Read

Check this box to allow remote reading of your CodeMeter Runtime Server over the network.

Remote Write

Check this box to allow a remote access to change the configuration settings of your CodeMeter Runtime Server.

HTML Archive

Here you may specify the language used in your CodeMeter WebAdministrator.


 

Backup:

 

 

Backup Path:

Here you may specify the Backup Path where the CmStick backup is written to.

The default Backup Path under Windows is [\CodeMeter\Runtime\bin].

Backup Interval:

Here you can specify the interval (in hours) when CodeMeter will automatically generate backups.

The default value is 24 hours.

You can also perform a backup immediately, instructions can be found on the Backup page.


 

Borrowing:

 

On the "Configuration | Borrowing" page you define entry-specific settings of a borrowed license. These settings overwrite the original programmed settings of the borrowed license.

This is only useful if your software vendor provides you borrowable licenses. A normal CodeMeter or CodeMeterAct license can't not be borrowed!

 

Overwrite Entry Settings

Activate the option Overwrite Entry Settings to allow overwriting the original license condition of the borrowed license.

Maximum Borrow Duration

Specify in the Maximum Borrowing Duration field the maximum time in minutes how long the license is to be borrowable.

Maximum Borrow Quantity

Specify in the Maximum Borrow Quantity field the maximum number of borrowed licenses to be borrowed.